產(chǎn)品特點(diǎn):SG-853 automatic balancing large-capacity centrifuge is the company according to the user experience,Carefully design and development of a new generation of centrifuges products

產(chǎn)品詳細(xì)資料:

SG-853 automatic balancing large-capacity centrifuge is  the company  according to the user experience,Carefully design and development of a new generation of centrifuges products, and compared to similar products with higher quality advantage:apply to the hospital laboratory, biochemistry laboratory for qualitative analysis, for plasma, serum, urea, and vaccine manufacturing use. is applicable to all types of laboratory samples of high-capacity centrifugal precision laboratory instruments.
Product features:
1, outstanding performance: micro-computer control, frequency control DC, brushless DC motor without carbon powder pollution;
2, simple: touch panel, digital display, intuitive and reliable;
3, high-capacity multi-rotor, the user easily select

Technical data:
Maximum speed: 5000r/min
No. 1 rotor: 2 *400ml
No. 2 rotor: 4 * 250ml
No. 3 rotor: 36 * 10ml
No. 4 rotor: 72 * 5ml
Motor: Brushless DC Motor
Timing range: 0-99min


Handling Precautions
Work in a high speed centrifuge, used to safety and to ensure that the equipment to maintain high precision work, we must do the following:
1.Centrifuges used to be placed in a smooth, strong on the counter; large-capacity high-speed low-speed centrifuge and refrigerated centrifuge to be placed accordingly on the ground in a solid, level place. Centrifuge work done, the load balancing, weight error as small as possible, otherwise it will cause severe vibration, and shaft damage turned centrifuge.
2.Centrifuge starts, switch knob should be on the low speed position, start and then gradually adjust to the desired value. A work, shall knob again transferred to low-bit work, at high speed block ban on direct start.
3.Rotor in the strict inspection before each use if a foreign body and the dirt hole, in order to maintain balance. Turned around and must be kept dry and clean, do not impact abrasion. Such as accidentally dropped, turned to X-ray film should check that no internal injury can continue to use. Turned after each use with warm water (50 Degrees -60 Degrees) and neutral detergent immersion cleaning, and finally with distilled or deionized water rinse, soft cloth after drying with hair dryer, wax, dry place.
4.Pull all kinds of tube length, strength and stretch are different, should the need to use, the tube can be made of many different materials, such as polyethylene, cellulose, polycarbonates, polypropylene. Use care to ensure the sample, non-corrosive materials, solvent and gradient centrifuge tube and cap components. Expired, the aging, there are cracks or corrosion of the tube by minimizing or spin-down use. Control the use of plastic tube number, pay attention to standard matching. Centrifugal process may open the centrifuge lid, not by hand or foreign body collisions are turned and the rotation of the centrifuge tube.
5. To ensure safety, be sure to use ground wire
6.In the centrifuge process, such as abnormal phenomena, such as the noise and vibration is not normal, should immediay stop checks, not to find reasons not to continue to operate .
7.Daily use of centrifuges in the process, every three months the level of response to host a degree of correction for each transfer using 500 million deal with a vacuum pump oil, working 500h should check drive motor carbon brush, preferably with a vacuum cleaner to friction toner remove, if necessary, to replace carbon brushes or commutator with fine sandpaper polish.Should be cleaned about every driver using the 1500h site with high-speed bearings and grease shaft and turned rust-proof joint of fat should be kept painted, do not be long-term anti-rust oil coating oil paper wrap. When not in use should be switched each month low 1 or 2 times, each time 0.5h, to ensure the normal operation of the site.
8. Be sure to place the centrifuge tube placed symmetrically, and to keep the weight fairly. Things in the open centrifuge to centrifuge lid.
9. Centrifugal liquid should not be too low boiling point,Should pay attention to internal

 相關(guān)同類(lèi)產(chǎn)品:

留言框

  • 產(chǎn)品:

  • 您的單位:

  • 您的姓名:

  • 聯(lián)系電話(huà):

  • 常用郵箱:

  • 省份:

  • 詳細(xì)地址:

  • 補(bǔ)充說(shuō)明:

  • 驗(yàn)證碼:

    請(qǐng)輸入計(jì)算結(jié)果(填寫(xiě)阿拉伯?dāng)?shù)字),如:三加四=7

上海碩光電子科技有限公司 版權(quán)所有

ICP備案號(hào):滬ICP備14032911號(hào)-5 管理登陸 技術(shù)支持:化工儀器網(wǎng)   總流量:492835  sitemap.xml

在線(xiàn)客服
  • 劉先生

    021-65682142

    13816422470

在線(xiàn)客服
用心服務(wù) 成就你我
亚洲熟妇短视频一区| 91精品国产欧美一区二区成人| 亚洲欧美激情精品一区二区三区| 天天精品天天综合网| 久久久伊人少妇熟女精品| 九久精品| 人妻丰满熟妇av无码一区二区| jiujiure国产最新视频| 91|午夜在线观看| 延吉市| 视频在线日韩| 国产日韩在线亚洲字幕中文| 亚洲精品无码久久久久不卡| 亚洲狠狠色丁香婷婷综合久久 | 欧美精品在线看| 丁香五月成人影院| 亚洲成av人片在www色猫咪| 五十路中文在线| 无码人妻AV一区二区三区连泽鹏| 久久婷婷激情综合色综合俺也去| 日欧在线观看一区二区三区四区| 欧美啊v视频在线| 亚洲无码国产精| 亚洲国产综合91精品久久| 国产日韩a欧美在线人成视频| 69天堂成人无码麻豆免费视频| 91精品国产91久久久久久不卡| 久久亚洲精品日韩高清| 欧美色吧日韩| 精品少妇偷人| 国产伦清品一区二区三区| 久久人码无妻| 啊片网址| 被干的日韩影音先锋| 乱日老妇视频| 17c国产一区二区| 欧美91成人| 少妇人妻系列无码视频专区| 欧美日批网| 欧美人交性视频在线香蕉视频| 中文字幕人妻永久在线|