歡迎來上海碩光電子科技有限公司!

產(chǎn)品名稱:large-capacity centrifuge

產(chǎn)品型號(hào):SG-852-type

更新時(shí)間:2019-05-05

廠商性質(zhì):生產(chǎn)廠家

訪問次數(shù):3285

產(chǎn)品報(bào)價(jià):

產(chǎn)品特點(diǎn):SG-852-type large-capacity centrifuge is the company according to the user experience,Carefully design and development of a new generation of centrifuges products

產(chǎn)品詳細(xì)資料:

Product Introduction:
SG-852-type large-capacity centrifuge is  the company  according to the user experience,Carefully design and development of a new generation of centrifuges products, and compared to similar products with higher quality advantage:apply to the hospital laboratory, biochemistry laboratory for qualitative analysis, for plasma, serum, urea, and vaccine manufacturing use. is applicable to all types of laboratory samples of high-capacity centrifugal precision laboratory instruments.
Product features:
1, outstanding performance: micro-computer control, frequency control DC, brushless DC motor without carbon powder pollution;
2, simple: touch panel, digital display, intuitive and reliable;
3, high-capacity multi-rotor, the user easily select
Technical data:
Maximum speed: 5000r/min
1 rotor: 4 * 100ml
No. 2 rotor: 8 * 50ml
No. 3 rotor: 28 * 10ml
Motor: Brushless DC Motor
Timing range: 0-99min


Handling Precautions
Work in a high speed centrifuge, used to safety and to ensure that the equipment to maintain high precision work, we must do the following:
1.Centrifuges used to be placed in a smooth, strong on the counter; large-capacity high-speed low-speed centrifuge and refrigerated centrifuge to be placed accordingly on the ground in a solid, level place. Centrifuge work done, the load balancing, weight error as small as possible, otherwise it will cause severe vibration, and shaft damage turned centrifuge.
2.Centrifuge starts, switch knob should be on the low speed position, start and then gradually adjust to the desired value. A work, shall knob again transferred to low-bit work, at high speed block ban on direct start.
3.Rotor in the strict inspection before each use if a foreign body and the dirt hole, in order to maintain balance. Turned around and must be kept dry and clean, do not impact abrasion. Such as accidentally dropped, turned to X-ray film should check that no internal injury can continue to use. Turned after each use with warm water (50 Degrees - 60 Degrees) and neutral detergent immersion cleaning, and finally with distilled or deionized water rinse, soft cloth after drying with hair dryer, wax, dry place.
4.Pull all kinds of tube length, strength and stretch are different, should the need to use, the tube can be made of many different materials, such as polyethylene, cellulose, polycarbonates, polypropylene. Use care to ensure the sample, non-corrosive materials, solvent and gradient centrifuge tube and cap components. Expired, the aging, there are cracks or corrosion of the tube by minimizing or spin-down use. Control the use of plastic tube number, pay attention to standard matching. Centrifugal process may open the centrifuge lid, not by hand or foreign body collisions are turned and the rotation of the centrifuge tube.
5. To ensure safety, be sure to use ground wire
6.In the centrifuge process, such as abnormal phenomena, such as the noise and vibration is not normal, should immediay stop checks, not to find reasons not to continue to operate .
7.Daily use of centrifuges in the process, every three months the level of response to host a degree of correction for each transfer using 500 million deal with a vacuum pump oil, working 500h should check drive motor carbon brush, preferably with a vacuum cleaner to friction toner remove, if necessary, to replace carbon brushes or commutator with fine sandpaper polish。Should be cleaned about every driver using the 1500h site with high-speed bearings and grease shaft and turned rust-proof joint of fat should be kept painted, do not be long-term anti-rust oil coating oil paper wrap. When not in use should be switched each month low 1 or 2 times, each time 0.5h, to ensure the normal operation of the site.
8. Be sure to place the centrifuge tube placed symmetrically, and to keep the weight fairly. Things in the open centrifuge to centrifuge lid.
9. Centrifugal liquid should not be too low boiling point,Should pay attention to internal and external pressure ratio.If it is toxic reagents, but also good ventilation treatment.
 

 相關(guān)同類產(chǎn)品:

留言框

  • 產(chǎn)品:

  • 您的單位:

  • 您的姓名:

  • 聯(lián)系電話:

  • 常用郵箱:

  • 省份:

  • 詳細(xì)地址:

  • 補(bǔ)充說明:

  • 驗(yàn)證碼:

    請(qǐng)輸入計(jì)算結(jié)果(填寫阿拉伯?dāng)?shù)字),如:三加四=7

上海碩光電子科技有限公司 版權(quán)所有

ICP備案號(hào):滬ICP備14032911號(hào)-5 管理登陸 技術(shù)支持:化工儀器網(wǎng)   總流量:492835  sitemap.xml

在線客服
  • 劉先生

    021-65682142

    13816422470

在線客服
用心服務(wù) 成就你我
精品久久折| 4388精品久久| 一区二区三区在线免费视频| 亚洲一二三区AV无码| 午夜免费福利视频| 久久国产乱子伦免费精品无码| 国产精品一级无码毛片视频| 成年人网站视频91| 成人黄色电影中文字幕| 欧美69AV久久久| 欧美日韩国产另类在线观看| 欧美日韩国产在线高清视频| 一级黄片好| 亚洲美女高潮视频| 那种视频你懂得| AV无码高潮网站| 欧美中文在线不卡| 91欧美亚洲国产| 最新国产女同精品视频| 国产精品欧美一区色| 啊啊啊无码视频| 鄂伦春自治旗| 国产欧美亚洲精品第一页在线| 日色噜噜无码| 欧美性爱99| 不雅视频 swag| 熟妇人妻精品一区二区三区视频| 色呦呦日本韩国| 亚洲AV无码专区一区| 无码专区涩爱网| 五月综合激情六月婷婷| 六月婷婷中文字幕| 丁香 五月 综合| 内射人妻少妇无码一本一道| 国产精品第一页综合在线| 久久久久久免费黄片| 蜜乳国产一区二区| 一区二区日韩无码| 777国产盗摄偷窥精品000下| 亚洲人妻精品无码一区二区三区 | 国户精品久久久久久久久久久不卡 |